<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-13 05-37-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.50 MHz 4/5, 50 dBuV ISKELMA
Pilot RDS Phase Difference
6.8 kHz 2.4 kHz -1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
22 kHz 66 kHz 3974 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
5,5 dBr 6,21 dBr 7,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 0 0 --:--
RT
-
AF EON
89.4, 92.5, 100.1, 107.7, 107.9 MHz -
FM Scope Max at: 66 kHz MIN: 22 kHz % above 76 kHz: 0,0000 Acquired: 2024/08/13 5.36.46 Total samples: 3974 Equivalent time: 0:03:18 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 7,0 dBr MIN: 5,5 dBr AVE: 6,21 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2024/08/13 5.36.46) 05.22 05.24 05.26 05.28 05.30 05.32 05.34 05.36 0 2 4 6 8 Pm [dBr]